0747/06

Floor lamp

Lighting equipmentElectric shockFire
Notifying country
Germany
Counterfeit
No
Sold online
No
Open the alert on the European Commission website ↗

What is the danger

- it is not stable due to its dimensions; - the transformer is not adequately secured, which means that it can come into contact with the metal casing of the lamp; - during the voltage stability test, there was a transformer flashover at 3100 V; - instructions for changing the bulb are incomplete; - assembly instructions are only in English. Risk of electric shock and fire. The product poses a risk of electric shock and fire because: The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  1. Withdrawal from the market and recall from consumers ordered by the authority. Compulsory measuresTaken by: Other

Product

Model / type
167180
Barcode
8716963159151

Original source

Data comes from the official Safety Gate system of the European Commission.

Alert number
0747/06 ↗
Weekly report
Report-2006-46
Published
23 November 2006

© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-11563