AC adaptor for TFT television/monitor “Denver” (television itself is not affected)
Electrical appliances and equipmentElectric shock
- Notifying country
- Finland
- Counterfeit
- No
- Sold online
- No
What is the danger
The product poses a serious risk of electric shock because: - the insulation between the parts connected to the mains (primary circuit) and parts that can be touched by the user (secondary circuit) is not sufficient. In particular: - creepage distances and clearances in the mains transformer between the primary windings and secondary windings are less than 5mm/4 mm (measured a minimum of 0.4 mm); - the secondary circuit is accessible through the terminals. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60065.
Measures taken
- Withdrawal from the market and recall from consumers ordered by the authority. Compulsory measuresTaken by: Other
Product
- Model / type
- Barcode
Original source
Data comes from the official Safety Gate system of the European Commission.
- Alert number
- 0753/06 ↗
- Weekly report
- Report-2006-46
- Published
- 23 November 2006
© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-11569