← All products
0020/07

Lighting chain

Unknown

Lighting equipmentElectric shock
Country of origin
Thailand
Notifying country
Spain
Counterfeit
No
Sold online
No
Open the alert on the European Commission website ↗

What is the danger

This product poses a serious risk of electric shock because: - the characteristics of the chain’s cable are lower than specified in the standard; - the nominal cross-section of the conductors is 0,36 mm², which is less than the 50 mm² required by the standard; - the length of the wire between the plug and the first bulb holder is 1,00 m, which is less than the 1,50 m required by the standard; - there are no safety markings and instructions. This product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  1. Import rejected by the customs authorities Compulsory measuresTaken by: Other

Product

Brand
Unknown
Model / type
Rose 20 NP-L

Original source

Data comes from the official Safety Gate system of the European Commission.

Alert number
0020/07 ↗
Weekly report
Report-2007-1
Published
11 January 2007

© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-11729