Lighting chain
Unknown
Lighting equipmentElectric shock
- Country of origin
- Thailand
- Notifying country
- Spain
- Counterfeit
- No
- Sold online
- No
What is the danger
This product poses a serious risk of electric shock due to the following non-compliances with the relevant European standard EN 60598: - the length of the wire between the plug and the first bulb holder is 1 m, which is less than the required 1,5 m; - the wire in the chain has inferior characteristics to those specified in the standard; - the nominal cross-section of the conductors is 0,36 mm², which is less than the required 50 mm²; - the required safety markings and instructions are missing. The product does not comply with the Low Voltage Directive.
Measures taken
- Import of the product has been rejected by the customs authorities Compulsory measuresTaken by: Other
Product
- Brand
- Model / type
Original source
Data comes from the official Safety Gate system of the European Commission.
- Alert number
- 0021/07 ↗
- Weekly report
- Report-2007-1
- Published
- 11 January 2007
© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-11730