Power supply units
Prescott
- Notifying country
- Finland
- Counterfeit
- No
- Sold online
- No
What is the danger
This product poses a risk of electric shock because - there is not sufficient electrical insulation between the primary circuit connected to the mains and the secondary circuit that can be touched. The secondary circuit can be touched via the product connected to the output of the power supply unit. In particular: - clearances/creepage distances in transformer T2 between the primary and the secondary windings are less than 4 mm/5 mm; a minimum of 0.2 mm between the primary winding and the output wires of the secondary winding and 0.5mm between the secondary winding and the output wires of the primary winding are measured; on the output wires there are not insulation tubes; - clearances/creepage distances in transformer T3 between the primary and the secondary windings are less than 4 mm/5 mm; a minimum of 0.3 mm between the primary winding and the output wires of the secondary winding and 0.3 mm between the secondary winding and the output wires of the primary winding are measured; on the output wires there are not insulation tubes. This product does not comply with the Low Voltage Directive and the relevant European standard EN 60950.
Measures taken
- Recall from consumers ordered by the authorities Compulsory measuresTaken by: Other
Product
- Brand
- Model / type
Original source
Data comes from the official Safety Gate system of the European Commission.
- Alert number
- 0271/07 ↗
- Weekly report
- Report-2007-11
- Published
- 22 March 2007
© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-11979