Gas detectors
HP POPP McTOXI
OtherInjuries
- Country of origin
- People's Republic of China
- Notifying country
- Spain
- Counterfeit
- No
- Sold online
- No
What is the danger
The product poses a risk of injuries because the alarm is only triggered once the lower explosion level has been surpassed. The gas detector is unsuitable for providing a warning of the risk of an explosion caused by leaking gas.
Measures taken
- Voluntary withdrawal from the market and recall from consumers by the manufacturer. Voluntary measuresTaken by: Other
Product
- Description
- Gas detectors for natural gases: butane, propane, methane and petroleum gas, etc. Dimensions: height: 100 mm, width: 76 mm, thickness: 43 mm, Voltage: 9 V DC, via power supply adaptor Acoustic alarm: 85 dB. Year of construction: 2006, First year of commercial distribution: 2007.
- Brand
- Model / type
Original source
Data comes from the official Safety Gate system of the European Commission.
- Alert number
- 1247/08 ↗
- Weekly report
- Report-2008-43
- Published
- 30 October 2008
- Corrigendum
- Corrigenda: Notification 1217/08 from week 42 of 2008 has been removed because after more investigations the product was found to be compliant with the relevant European requirements. Notification 1081/08 from week 39 in 2008 has been updated
© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-14294