← All products
A12/01053/20

Bus

CNG12; CNG10,5; NBG12; BNG 10,5; NSG12

Motor vehiclesFireInjuries
Country of origin
Czechia
Notifying country
Czechia
Counterfeit
No
Sold online
No
Professional product
Yes
Open the alert on the European Commission website ↗

What is the danger

The pressure relief device of the compressed natural gas (CNG) tank might not properly vent when necessary. Consequently, if the CNG tank is exposed to heat, it may break and leak gas increasing the risk of fire or explosion.

Measures taken

  1. All Emer Pressure Relief Device (PRD valves) will be change Compulsory measuresTaken by: Manufacturer

Product

Description
Bus
Model / type
e8*2007/46*0048*06e8*2007/46*0059*09e8*2007/46*0059*10e8*2007/46*0067*04e8*2007/46*0313*04
Batch
BNG 10,5, e8*2007/46*0048*06, 2019CNG 12, e8*2007/46*0059*09, 05/2019 - 12/2019CNG 12, e8*2007/46*0059*10, until 05/2020CNG10,5, e8*2007/46*0048*06, 2019NBG12, e8*2007/46*0067*04, 2019NSG12, e8*2007/46*0313*04, until 07/2020

Original source

Data comes from the official Safety Gate system of the European Commission.

Alert number
A12/01053/20 ↗
Weekly report
Report-2020-29
Published
15 July 2020
Modified
15 July 2020

© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10001627

Your reaction
Found a mistake? Let us know

Only the site administrator will see your message.