← All products
A12/03632/24

Passenger car

Lexus | Toyota · AURIS TMUK, C-HR TMMT, COROLLA TMUK, NX200, RX300

Country of origin
UK
Notifying country
Portugal
Counterfeit
No
Open the alert on the European Commission website ↗

What is the danger

Insufficient pressing of parts in the high pressure fuel pump can cause movement of the cylinder in the fuel pump through which the piston moves. This can create wear between the cylinder and the pump body, resulting in increased stress on valves and/or movement valve seat inside the pump body. This increased stress can cause a crack in the weld of the affected valves, which could lead to a fuel leak, increasing the risk of fire.

Requirements breached

The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.

Measures taken

  1. Recall of the product from end users Voluntary measuresTaken by: Importer

Product

Description
Passenger car. Model (Production dates, model code): AURIS TMUK (04.05.2018 - 30.11.2018, NRE185), C-HR TMMT (07.05.2018 - 04.02.2022, NGX10, NGX50), COROLLA TMUK (18.12.2018 - 08.11.2022, NRE210), NX200 (12.09.2017 - 01.07.2021, AGZ10, AGZ15), RX300 (29.03.2018 - 29.09.2022, AGL25).
Packaging
Countries of production: Turkey and United Kingdom. In Portugal this Recall Campaign covers models: AURIS TMUK, C-HR TMMT and COROLLA TMUK. The subject vehicles were involved in a previous campaign announced in October 2023 and June 2024 for high-pressure fuel pump installed on 8NR and 8AR engines
Brand
LexusToyota
Model / type
e11*2001/116*0305*21e11*2007/46*3641*01e6*2007/46*0318*00e6*2007/46*0318*01e6*2007/46*0318*02e6*2007/46*0318*03e6*2007/46*0318*04e6*2007/46*0318*05e6*2007/46*0318*06e6*2007/46*0338*00
Barcode
24SD-149
Batch
2018 - 2022

Original source

Data comes from the official Safety Gate system of the European Commission.

Alert number
A12/03632/24 ↗
Weekly report
Report-2024-50
Published
2 June 2025
Modified
26 June 2026
Corrigendum
Notification A12/03588/24 has been withdrawn at the request of the notifying authority following a retesting of the product.

© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10092407