← All products
A12/1953/14

Laser hair remover

Biotechnique Avance · Unknown

Electrical appliances and equipmentDamage to sightElectric shockInjuries
Country of origin
United States
Notifying country
Germany
Open the alert on the European Commission website ↗

Requirements breached

It is a class 4 laser product and the laser beam could cause injury to the eyes and the skin and damage to sight. The wavelength of the laser light is outside the range of visible optical radiation which means that the user cannot see the laser beam and may think that it is not working. The laser beam does not focus to a point. There are no instructions for use. The electrical insulation is not adequate and the product is not earthed which could lead to a risk of electric shock. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standards EN 60335 and EN 60825-1 (the latter with respect to the provision of safety information).

Measures taken

  1. Import rejected at border Compulsory measuresTaken by: Other

Product

Description
Laser hair removal device for home and professional use. Labelled as a Class 4 laser product.
Brand
Biotechnique Avance
Model / type
Quazar DM 6000 / Model # XSR 256-30114
Batch
Unknown

Original source

Data comes from the official Safety Gate system of the European Commission.

Alert number
A12/1953/14 ↗
Weekly report
Report-2014-049
Published
3 December 2014
Corrigendum
Notification A12/1818/14 published on report 46-2014 of 21/11/2014 has been modified following notifying authority's instructions.