Concrete mixer pump
Cifa · Autobetonpompa / Truck-mixer pump
MachineryInjuries
- Country of origin
- Italy
- Notifying country
- Poland
- Counterfeit
- No
- Professional product
- Yes
Requirements breached
The strength of the outrigger pillar is insufficient due to a fault of the structure material. During pouring of concrete, when the boom of the pump is in its maximum horizontal position, the construction breaks and hits workers who are present in the working zone of the boom. The product does not comply with the requirements of the Machinery Directive. Four fatal accidents were reported.
Measures taken
- Recall of the product from end users Voluntary measuresTaken by: Other
Product
- Description
- Product is installed on the chassis of the truck and intended for mixing and dispensing of concrete.
- Brand
- Model / type
- Batch
Original source
Data comes from the official Safety Gate system of the European Commission.
- Alert number
- A12/1191/16 ↗
- Weekly report
- Report-2016-039
- Published
- 22 September 2016
- Corrigendum
- Notification A12/0041/16 in Report-2016-003 has been withdrawn following a revised risk assessment by the notifying authority.
© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/226133