Gas fire
GAZCO · Flue Logic HE, E-Box and E-Studio
Gas appliances and componentsAsphyxiation
- Country of origin
- UK
- Notifying country
- UK
- Counterfeit
- No
- Sold online
- No
Requirements breached
Aluminium rivets were used instead of steel rivets for the fixings for the draught diverter plate. Failure of the rivets could lead to the draught diverter plate moving out of position which, in combination with the failure of the safety cut off switch, could cause carbon monoxide to enter the room. The product does not comply with the requirements of the Gas Appliances Directive.
Measures taken
- Retro fit of adaption plate to prevent baffle plate movement Voluntary measuresTaken by: DistributorIn force from: 16 March 2017
- Warning consumers of the risks Voluntary measuresTaken by: ManufacturerIn force from: 16 March 2017
Product
- Description
- Chimney/flue gas-fired heaters, no packaging.
- Brand
- Model / type
- Batch
Original source
Data comes from the official Safety Gate system of the European Commission.
- Alert number
- A12/0733/17 ↗
- Weekly report
- Report-2017-023
- Published
- 31 May 2017
© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/261930