← Ко всем товарам
A12/1886/12

Fluorescent lamp

Maxi Light · Rota

Осветительное оборудованиеПоражение электрическим током
Страна происхождения
Китай
Страна, подавшая оповещение
Венгрия
Открыть оповещение на сайте Еврокомиссии ↗

Нарушенные требованияEN

The product poses a risk of electric shock because: · The cable ends are not adequately protected against pulling and twisting. · The accessible basic insulated wires can come into contact with sharp edges of the cable entry. In case of damage to the wires, the live metal conductors become accessible. · The phase and neutral terminals are not identified. If the mains supply is connected incorrectly, live metal parts become accessible. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

ТоварEN

Описание
Lamp with a fluorescent tube. It has a 1.3 m long mains supply cable connected to a binominal terminal. It also has a separate built-in socket plug.
Бренд
Maxi Light
Модель / тип
Model: CH242; ART.NR.304010
Партия
Unknown

Первоисточник

Данные получены из официальной системы Safety Gate Европейской комиссии. Тексты описаний приводятся в оригинале на английском, если для них нет проверенного перевода.

Номер оповещения
A12/1886/12 ↗
Недельный отчет
Report-2012-051
Опубликовано
14 декабря 2012 г.
Исправление
<font color="#ff0000"><b>Corrigendum</b></font><br/> Notification 0510/12 from week 13 of 2012 has been withdrawn from the RAPEX application and from the RAPEX website following a revised risk assessment.

© European Union, Safety Gate · https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/54914

Как вам?
Нашли ошибку? Сообщите нам

Сообщение увидит только администратор сайта.